What Comes Out of the Wall

The exact supply values behind a Mexican socket, and which device label ranges are safe to plug in.

Mexico runs 120/240 V split-phase for residential service and 127/220 V three-phase for larger installations, both at 60 Hz. The outlet you use normally sits on the lower leg, so plan against 127 V.

Plug geometry is fixed by NMX-J-163-ANCE and allows two types: type A, two flat parallel pins with no ground, and type B, the same two pins plus a round grounding pin. Anything else — European two-round-pin, UK three-rectangular-pin — needs a mechanical adapter before it will enter the socket.

Frequency is 60 Hz across the whole system. This matters for devices with motors or timing circuits: a 50 Hz-only device sees a supply 20% faster than rated, which shows up as fast-spinning motors or clocks that drift.

The signature mark of this site, drawn as a plate

On narrow screens, swipe or scroll the plate sideways.

The table below pairs common device label ranges with what happens when you plug them into a 127 V, 60 Hz outlet. Use it as a quick screen before you go through the full adapter-or-transformer procedure.

A label reading 110–127 V, 60 Hz is an exact match. A label reading 100–240 V, 50/60 Hz covers the supply with margin. A label reading 220 V only falls outside the range entirely and must not be plugged in.

Nominal values are what the standard specifies; the actual voltage at a given socket varies with load and distance from the transformer, but the nominal figure is the correct basis for deciding compatibility.

  • Split-phase: 120/240 V, 60 Hz
  • Three-phase: 127/220 V, 60 Hz
  • Plug types: A and B under NMX-J-163-ANCE
  • Safe label ranges: 110–127 V 60 Hz, or 100–240 V 50/60 Hz
  • Unsafe label range: 220 V only